KYL-816 Analog Wireless Acquisition module Use Manual
Shenzhen KYL Communication Equipment Co., Ltd
Address: Unit 5-7, Building3, Huangdu Square, South of Exhibition Center, Yitian Road, Futian District, Shenzhen Guangdong China Tel: +86-0755-83410815 Fax: +86-0755-83408785 Skype Skypelxmlosia Yahoo messenger: losia2012@yahoo.com MSN: kylcom01.com@hotmail.com E_mail: sales01@rf-data.com/kyl03losia@gmail.com Website: http://www.rf-data.com
Fax: +86-0755-83408785
kyl03losia@gmail.com
www.rf-data.com
Shenzhen KYL Communication Equipment Co., Ltd Shenz Co.
KYL-816 Analog Wireless Acquisition Module has the function for analog acquisition and wireless transmission, do not re-empolderit can achieve the function for wireless remote controlling and collecting data with a low cost. It is industrial design and has a wide work temperature so that can meet client's requirement for whole day using. Besides, the RF adopts narrowband FM and has high anti-jamming. Accord with EN300220.
Feature: IFeature:
1Analog: two channels 0-5V voltage input and two channels 0-5V voltage output 2Power supply: 12-14V, providing protection for power supply in reverse 3. There are power monitor circuit and watch dog circuit for the CPU, and ensure that this module can operate at adverse circumstances. 4With the indicator light of power supply, operation, receive and transmit. 5Can work by Modubus RTU protocol.
II Technical parameters IITechnical
1Analog12BIT ADC; Precision 0.5% ; input typevoltage 05V. 2Impedance Input20M. 3Frequency433MHz 4Modulation: FSK 5Output power 500mW 6Transmit current <350mA 7Receive sensitive-123dBm (1200bps) 8Receive current <50mA 9Antenna impedance50 10Communication distanceAbove 3Km (BER=10-5@1200bpsin the open air)
Fax: +86-0755-83408785 kyl03losia@gmail.com
www.rf-data.com
Shenzhen KYL Communication Equipment Co., Ltd Shenz Co.
11Work temperature-35+75(industrial) 12. Size13.8*9.0*4.0CM
III Instruction of the indicator light IIIInstruction
1Indicator light for the power supplypower supply indication; 2 Indicator light for working indication for the equipment working in gear, the bicker period is 2S when the equipment work in gear. 3Indicator light for transmitindication for data transmitting. 4Indicator light for receiveindication for data receiving.
IV Use method IVUse
1The use method of KYL-816 1 point to point transmission mode initiatively: The transmission equipment will acquisition voltage analog signal for 0-5V timing, code and wireless transmit; and the receiving equipment receive, code and output voltage analog signal for 0-5V.That is the input voltage from the receiving equipment will be changed with the output voltage from the transmission equipment. The timing transmission interval can set from 10mS to 60S.When it is set as "000",KYL-816 acquisition module just as a receiving equipment, it will not transmit any data; When it is not set as "0",KYL-816 acquisition module as transmission equipment, it will transmit acquisition data according to the time interval which has been set. But the minimum transmission interval is relative with the transmitting distance, so please make out before order. 2 Principal and subordinate acquisition mode. When the receive equipment don't need show the input voltage from the transmission equipment, but need transmit the acquisition data to the PC or other terminal equipment, now the system will use the Principal and subordinate mode. The
Fax: +86-0755-83408785 kyl03losia@gmail.com
www.rf-data.com
Shenzhen KYL Communication Equipment Co., Ltd Shenz Co.
Principal equipment will be the PC or other terminal equipment which will connect with a wireless transceiver module(such as KYL-320I); And the subordinate equipment will be a acquisition unit which have a address code with the number of 0-255(the timing transmission interval for the KYL-816 set as"0").Under this mode, the wireless transceiver module will transmit acquisition command so that the principal equipment will charge 255 acquisition module . 2Parameters setting
Picture one Software for setting parameter As the above picture shows: Clients can set some parameters by the KYL-80X software, including the below parameters:
Fax: +86-0755-83408785 kyl03losia@gmail.com
www.rf-data.com
Shenzhen KYL Communication Equipment Co., Ltd Shenz Co.
1Module address: from 000 to 255; 2Channel: total eight channels, each channel have different frequency; 3Transmission interval: it will be in effect only for the module under the point to point transmission mode. The minimum interval will be different from the baud
rate of the module. When it set as "000",the module work at the subordinate mode and will receive or output data. 3Use of the software 1Connect the module with the PC and open the software of KYL-80X, then choose the right port. 2Electrify, if connect success, the software will show " read success". Then "read ID", read success, then can change the parameter. Note: 1 When set or read parameter, first need input the appointed ID that is the current module address; also can know the current module address by "read ID", the " write ID" command can change the current module address. 2 When set the channel, it can't exceed the max number channel for eight channels. And the two module will be set the some channel, or they will not communicate. 3Also can change the parameter by wireless. Connect the wireless data module with the PC by UART port(not the UART port of the KYL-816),then can change the parameter of the KYL-816. 4 Under the point to point mode, many double equipment work at the same time, different double equipment should be set different channel.
Fax: +86-0755-83408785
kyl03losia@gmail.com
www.rf-data.com
Shenzhen KYL Communication Equipment Co., Ltd Shenz Co.
Picture two: connection for setting parameter
V: Connection Definition
1Pin Difinition Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Function VCC (Power supply input) GND ON-OFF output GND Relay no power output Relay no power output NC GND Second channel analog voltage GND First channel analog voltage input GND Second channel analog voltage GND First GND channel analog voltage Signal Ground Signal Ground Signal Ground Signal Ground Signal Ground Definition DC12-24V Grounding of power supply power controlling output (5V) Signal Ground Remarks
Connection Connection sketch map
Fax: +86-0755-83408785
kyl03losia@gmail.com
www.rf-data.com
Shenzhen KYL Communication Equipment Co., Ltd Shenz Co.
Picture three: Connection sketch map
Fax: +86-0755-83408785
kyl03losia@gmail.com
www.rf-data.com


▲Up To Search▲   

 
Price & Availability of KYL-816

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X